
Single anterior tooth
Dr. Joan Faus López
Implant placement in the anterior region, followed by abutment connection.
More cases on InstagramFree shipping on orders of USD 500 or more · Express delivery
Licensed professionals · FDA 510(k) · CE MDR
Alef implant system
Tapered, self-tapping implant with a spiral internal hex and SLA surface.
$125.00per implantper implant · same price for every size
Pick every size you need in one chart, then add all to the cart.
Check compatibilityUse − and + in each size, or type the quantity. Then add everything to your cart in one step.
Alef shares its connection with the following implant systems. Always confirm the exact platform before ordering.
| Brand | Lines | Connection |
|---|---|---|
| Alpha Bio Tec | SPI, ATID, DFI, ICE, SFB | Ø3.5 platform, 2.43 hex |
| Noris Medical | Internal hex implants | Ø3.5 platform, 2.43 hex |
| Zimmer | Screw-Vent, Tapered Screw-Vent, Trabecular Metal, Core-Vent SD | Ø3.5 platform, 2.43 hex |
| ADIN | Swell, Touareg, Touareg-S | Ø3.5 platform, 2.43 hex |
| MIS | BioCom, Lance, Lance Plus, M4, Seven | Ø3.5 platform, 2.43 hex |
| BioHorizons | Internal, Tapered Internal, Tapered Internal Plus | Ø3.5 platform, 2.43 hex |
| Implant Direct | Legacy 1–4 | Ø3.5 platform, 2.43 hex |
| Glidewell | Inclusive Tapered | Ø3.5 platform, 2.43 hex |
| Blue Sky Bio | Internal Hex | Ø3.5 platform, 2.43 hex |
| A.B. Dental | I2, I2b, I5, I10, I15 | Ø3.5 platform, 2.43 hex |
| Alpha Dent | Active, Active Bio, Classic | Ø3.5 platform, 2.43 hex |
| Cortex | Classic, Classix, Dynamic, Dynamix | Ø3.5 platform, 2.43 hex |
| Dentin | Classic, Prestige, Rapid | Ø3.5 platform, 2.43 hex |
| Sigma Implants | Sigma Active, Sigma Classic | Ø3.5 platform, 2.43 hex |
| Nova Implants | Pacific, Spirit | Ø3.5 platform, 2.43 hex |
| Top Implants | Dolphin, Orca, T-Shark | Ø3.5 platform, 2.43 hex |
| TAV Dental | Silhouette, Sirius | Ø3.5 platform, 2.43 hex |
| Hi-Tec Implants | Logic Plus, Tapered Self Thread, X6 | Ø3.5 platform, 2.43 hex |
Components of Alef, Til and Conix are not interchangeable with each other. eIFU · Contact MSDI
Components that are usually ordered with this item.
Real cases placed by clinicians who work with MSDI implants.

Dr. Joan Faus López
Implant placement in the anterior region, followed by abutment connection.
More cases on Instagram
AlefOdontosix MSDI Implants
An Alef implant on the insertion driver, just before placement.
Dr. Luca Barbera, Milan
A multicenter clinical study carried out with 54 MSDI Alef implants.
Ask us for the studyDimensions for every Alef diameter. All measurements are in mm.
| Implant Ø | Apical Ø | Apex Ø | Lengths |
|---|---|---|---|
| Ø3.5 | 2.7 | 1.7 | 8, 10, 11.5, 13, 16 |
| Ø3.75 | 2.9 | 1.9 | 8, 10, 11.5, 13, 16 |
| Ø4.2 | 3.35 | 2.35 | 6, 8, 10, 11.5, 13, 16 |
| Ø5.0 | 4.15 | 3.15 | 6, 8, 10, 11.5, 13, 16 |
| Ø6.0 | 5.15 | 4.15 | 6, 8, 10, 11.5, 13 |
From the MSDI R7 product catalog. Always read the instructions for use.
Every Alef implant has an SLA surface: Sand-blasted, Large-grit, Acid-etched. Zoom in from the implant to the electron microscope to see the texture that bone grows onto.
Move over the image, or press and drag on mobile, to use the magnifier.
1× · The Alef implant. The whole implant body, threads and apex carry the same SLA treatment.
50× · Thread profile and apex. The apex of an Alef implant under the scanning electron microscope. You can see the thread profile, the cutting flutes that make the implant self-tapping, and the even matte texture that covers threads, flanks and core alike.
400× · The SLA texture. Overlapping craters left by grit blasting, with a finer etched texture inside and between them. The scale bar is 400 µm.
The titanium implant is blasted with coarse grit particles. This creates the first level of roughness: craters and ridges tens of microns wide across the threads and the core.
The blasted surface is then etched in acid. Etching softens the sharp peaks left by blasting and adds a second, finer layer of micro-pits a few microns across, on top of the craters.
Each implant is packed in a sealed tube and held in a titanium sleeve, so the treated surface is not handled before it reaches the osteotomy.
Two scales of roughness on one surface: the blasted craters give bone room to grow into, and the etched micro-pits give cells and proteins a texture to hold on to.
A rough surface has far more area than a smooth, machined one of the same size, so there is more surface for bone to contact.
Research on SLA surfaces shows that bone-forming cells attach and spread well on moderately rough titanium.
The micro-pits retain the blood clot and proteins that start healing, which is the first step of osseointegration.
As new bone grows into the craters and pits, it locks with the surface, which supports implant stability during healing.
Drill sequence for every Alef diameter. Choose the bone density, then follow the drills from left to right. Drill diameters are in mm.
Cortical drillThe last, widest drill goes only through the cortical layer, about the top third of the depth, not to full length. Alef implants are self-tapping, so the threads cut their own path in the bone below.
Max 60 NcmMaximum recommended insertion torque for Alef implants. Torque values do not replace clinical judgment.
Protocol from the MSDI R7 product catalog. Always read the instructions for use before surgery.
MSDI implant packaging is designed for efficiency, safety, and ease of use. Its patented delivery system ensures precise placement, giving clinicians full control and enabling reliable, predictable outcomes.

The Alef implant is a tapered, self-tapping internal-hex dental implant with an SLA-treated surface, double-lead threads and a round apex. Its platform-switching, spiral design supports primary stability in a range of bone densities. It is available in five diameters (Ø3.5–6.0 mm) and lengths from 6 to 16 mm.
Select diameter and length above. Each size has its own reference code (SKU), for example AL4210 = Ø4.2 × 10 mm.
MSDI products meet the highest standards set by the FDA, CE MDR, ISO 13485 and other regulatory bodies. Some products may not have regulatory clearance for sale in specific territories. See the instructions for use (IFU).
An SLA (sandblasted, large-grit, acid-etched) surface.
Up to 60 Ncm for the implant.
Diameters Ø3.5, 3.75, 4.2, 5.0 and 6.0 mm in lengths of 6 to 16 mm, depending on diameter.
The IFU is available at eifu.msdi-dental.com.